| Date | Class | Status | Apartment | Summary |
|---|---|---|---|---|
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR JOINTS AT SOUTH WALL AT BUILDING ENTRANCE AT FRONT AREAWAY, 1st STORY |
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICKS AND MORTAR JOINTS AT NORTH WALL AT PARAPET WALL AT PUBLIC HALL |
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DEFECTIVE MORTISE LOCK ON ROOF DOOR AT PUBLIC HALL |
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE FIRE DOOR AT PUBLIC HALL, 6th STORY |
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXY GLASS AT UPPER WINDOW SASH AT NORTH SECTION AT PUBLIC HALL, 4th STORY |
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXY GLASS AT LOWER WINDOW SASH AT NORTH SECTION AT PUBLIC HALL, 3rd STORY |
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXY GLASS AT UPPER WINDOW SASH AT NORTH SECTION AT PUBLIC HALL, 2nd STORY |
| Mar 23, 2026 | B | VIOLATION CLOSED | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MORTIE LOCK ON BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY |
| Mar 23, 2026 | C | VIOLATION CLOSED | Not available | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANE AT EAST AND WEST WINDOWS OF EAST WALL AT PUBLIC HALL, 1st STORY |
| Mar 5, 2026 | C | VIOLATION DISMISSED | F7 | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR TO FIRE ESCAPE IN THE 2nd ROOM FROM EAST LOCATED AT APT F7, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 5, 2026 | C | FIRST NO ACCESS TO RE- INSPECT VIOLATION | F7 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT F7, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 5, 2026 | A | VIOLATION DISMISSED | F7 | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS, CEILINGS AND TRIM IN THE ENTIRE APARTMENT LOCATED AT APT F7, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 5, 2026 | B | VIOLATION CLOSED | F7 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT F7, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 5, 2026 | B | VIOLATION CLOSED | F7 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT F7, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 5, 2026 | C | VIOLATION DISMISSED | F7 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT F7, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH |
| Mar 5, 2026 | B | VIOLATION CLOSED | B1 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE KITCHEN LOCATED AT APT B1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | C | VIOLATION CLOSED | B1 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH AT NORTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT B1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | C | VIOLATION WILL BE REINSPECTED | B1 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGE IN THE ENTRANCE LOCATED AT APT B1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | A | VIOLATION CLOSED | B1 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MOLD AT SOUTH WALL WINDOW APPROX. 5 SQ. FT. IN THE BATHROOM LOCATED AT APT B1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | B | VIOLATION CLOSED | B1 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT B1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | B | VIOLATION CLOSED | A8 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | B | VIOLATION CLOSED | A8 | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | B | VIOLATION CLOSED | A8 | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | B | VIOLATION CLOSED | A8 | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | C | VIOLATION CLOSED | A8 | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT RATS IN THE ENTIRE APARTMENT LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | A | VIOLATION CLOSED | A8 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE TOWEL RACK IN THE BATHROOM LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | B | VIOLATION CLOSED | A8 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WASH BASIN VANITY IN THE BATHROOM LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | B | VIOLATION CLOSED | A8 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | C | VIOLATION CLOSED | A8 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Mar 5, 2026 | C | VIOLATION CLOSED | A8 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... THE CEILING AT WEST AND SOUTH WALL APPROX 30 SQ. FT. IN THE BATHROOM LOCATED AT APT A8, 1st STORY, 1st APARTMENT FROM NORTH AT EAST |
| Feb 26, 2026 | B | VIOLATION CLOSED | 3F | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Feb 26, 2026 | C | VIOLATION CLOSED | 3F | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND ALL WALLS APPROX. 30 SQ. FT IN THE BATHROOM LOCATED AT APT 3F, 5th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Feb 11, 2026 | C | VIOLATION CLOSED | 3F | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND WALLS EQUAL TO 35 SQ. FEET IN THE BATHROOM LOCATED AT APT 3F, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Feb 11, 2026 | B | VIOLATION CLOSED | 3F | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST |
| Feb 10, 2026 | C | VIOLATION CLOSED | A2 | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT A2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NORTH'' |
| Feb 10, 2026 | A | VIOLATION CLOSED | A2 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH WALL IN THE BATHROOM LOCATED AT APT A2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NORTH'' |
| Feb 10, 2026 | C | VIOLATION CLOSED | A2 | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LEAKING RADIATOR SHUT-OFF VALVE IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT A2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''NORTH'' |
| Feb 10, 2026 | C | VIOLATION CLOSED | E1 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH '' |
| Feb 10, 2026 | C | VIOLATION CLOSED | E1 | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES LIGHT SWITCH AT NORTH WALL IN THE BATHROOM LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' |
| Feb 10, 2026 | C | VIOLATION CLOSED | E1 | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE FOYER LOCATED AT APT E1, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' |
| Feb 7, 2026 | C | VIOLATION CLOSED | A9 | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | B | VIOLATION CLOSED | A9 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | B | VIOLATION CLOSED | A9 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | C | VIOLATION CLOSED | A9 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | C | VIOLATION CLOSED | A9 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ FT AT EAST WALL (150 SQ FT) AND SOUTH WALL(144 SQ FT) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | B | VIOLATION CLOSED | A9 | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | C | VIOLATION CLOSED | A9 | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT BATHTUB BY METHOD OF REGLAZING IN THE BATHROOM LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | C | VIOLATION CLOSED | A9 | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ FT AT CEILING (30 SQ FT), NORTH WALL ( 20 SQ FT), WEST WALL (35 SQ FT), AND EAST WALLS (18 SQ FT) IN THE BATHROOM LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | B | VIOLATION CLOSED | A9 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL, EAST WALL, SOUTH WALL AND WEST WALLS IN THE BATHROOM LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |
| Feb 7, 2026 | C | VIOLATION CLOSED | A9 | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT A9, 1st STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' |